{"product_id":"mecer-2000va-1600w-online-ups-black-me-2000-tophatters-armory-deals-online","title":"MECER 2000VA \/ 1600W ONLINE UPS - BLACK ( ME-2000- - Tophatter's Army Deals","description":"\u003ch1\u003e\u003cspan style=\"text-decoration: underline;\"\u003eMECER 2000VA \/ 1600W ONLINE UPS - BLACK ( ME-2000-\u003c\/span\u003e\u003c\/h1\u003e\u003cp\u003eGuard your PC from unexpected power outages with the MECER 2000VA\/1600W ONLINE UPS in black. Keep your computer running smoothly through power surges and load shedding with this affordable, sleek and effective mountable UPS.\u003c\/p\u003e\u003cp\u003eNo more worries about flickering lights or unreliable electricity with this reliable uninterruptible power supply. Don't let power disruptions stop you from getting your work done - invest in the MECER 2000VA\/1600W ONLINE UPS today!\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/span\u003e:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTrue double-conversion online UPS\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eWide input voltage range (110-300 VAC)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInput power factor correction 0.99\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput power factor 0.8\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eConverter mode available\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eECO mode operation for energy saving (only available for 1-3KVA)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot-swappable battery design only available for 1-3KVA\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGenerator compatible\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjustable charging current via LCD or software (1A ~ 6A)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEmergency power off function only available for 6K and up models\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECS\u003c\/strong\u003e\u003c\/span\u003e:\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle phase with ground\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eINPUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e55-150 VAC or 110-300 VAC (Based on load at 50%); 85-140VAC or 160-280VAC (Based on load at 100%)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120\/127VAC or 200\/208\/220\/230\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e40Hz ~ 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 0.99 @ Nominal Voltage (100% load)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUTPUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120\/127VAC or 200\/208\/220\/230\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003e50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eTransfer Time: AC to Battery Mode\u003c\/td\u003e\n\u003ctd\u003eZero\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eTransfer Time: Inverter to Bypass\u003c\/td\u003e\n\u003ctd\u003e4 ms (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eTransfer Time: Waveform (Batt. Mode)\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eCurrent Crest Ratio\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e3% THD (Linear Load); 6% THD (Non-linear Load)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eFrequency Range (Synchronized Range)\u003c\/td\u003e\n\u003ctd\u003e47\u003cdel\u003e53 Hz or 57\u003c\/del\u003e63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEFFICIENCY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eBattery Mode\u003c\/td\u003e\n\u003ctd\u003e0.87\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAC Mode\u003c\/td\u003e\n\u003ctd\u003e0.89\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBATTERY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLong-run Model: Battery Type\u003c\/td\u003e\n\u003ctd\u003eDepending on the capacity of external batteries\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLong-run Model: Charging Current (max.)\u003c\/td\u003e\n\u003ctd\u003e1A\/2A\/4A\/6A (Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLong-run Model: Charging Voltage\u003c\/td\u003e\n\u003ctd\u003e54.7 VDC ± 1%, 82.1 VDC ± 1%, 109.4VDC ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLong-run Model: Numbers\u003c\/td\u003e\n\u003ctd\u003e4, 6, 8\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eStandard Model: Battery Type\u003c\/td\u003e\n\u003ctd\u003e12 V \/ 9 AH\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eStandard Model: Charging Current (max.)\u003c\/td\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eStandard Model: Charging Voltage\u003c\/td\u003e\n\u003ctd\u003e54.7 VDC ± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eStandard Model: Numbers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eStandard Model: Typical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e4 hours to recover to 90% capacity\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eINDICATORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003ctd\u003eLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eALARM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eBattery Mode\u003c\/td\u003e\n\u003ctd\u003eSounding every 4 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLow Battery\u003c\/td\u003e\n\u003ctd\u003eSounding every second\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003eSounding twice every second\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eFault\u003c\/td\u003e\n\u003ctd\u003eContinuously sounding\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eENVIRONMENT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e20~90% RH @ 0-40°C (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003eLess than 50dB @ 1 Meter\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePHYSICAL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eStandard Model: Dimension (mm)\u003c\/td\u003e\n\u003ctd\u003e410 x 438 x 88 [2U]\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eStandard Model: Net Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLong-run Model: Dimension (mm)\u003c\/td\u003e\n\u003ctd\u003e410 x 438 x 88 [2U]\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eLong-run Model: Net Weight (kgs)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMANAGEMENT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eOptional SNMP\u003c\/td\u003e\n\u003ctd\u003ePower management from SNMP manager and web browser\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eSmart RS-232\/USB\u003c\/td\u003e\n\u003ctd\u003eSupports Windows 2000\/2003\/XP\/Vista\/2008, Windows 7\/8\/10, Linux, and MAC\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"NeonSales","offers":[{"title":"Default Title","offer_id":51831085826386,"sku":"6585","price":5899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/7039\/1890\/files\/mecer-2000va-1600w-online-ups-black-me-2000-neonsales-shop-shopifycountryname-85473.png?v=1761125523","url":"https:\/\/tophatters.co\/products\/mecer-2000va-1600w-online-ups-black-me-2000-tophatters-armory-deals-online","provider":"Tophatter's Inc.","version":"1.0","type":"link"}